Functional Specifications
RF air protocol EPC Global Class1Gen 2; ISO/IEC
Operating frequency 902-928 MHz (US); 866-868 MHz (EU)
IC type Qstar-56GN
Memory configuration 496-EPC bits;2K-bit user memory;256-bit TID
Functionality Read / write (user programmed)
Memory – expected read / write cycles 100,000 cycles at 77°F (25°C)
Memory Banks MB 00 "RESERVED" MB 01 "EPC"
  MB 10 "TID" MB 11 "USER"
Data retention Up to 50 years
Read rate 1000 tags per second for 96-EPC bit number
Warranty (limited) 6 months
Applicable surface Metal surfaces
Material Engineering-grade nylon polymer
Color Charcoal
Weight 1.06 oz (30 g)
Standard Compliance VDA3-compatible data, ready for EDI
  VDA 5500, 5501,5509, 5510, 5520
Performance Characteristics
Read range on-metal (2W ERP) 2 Up to 23 ft (7 m)
Polarization Linear
1 Refer to the Structure of the Memory Banks (ISO/IEC 18000-63)
2 The chip data retention is based on chip operating under general environment conditions.
3 VDA: German Association of the Automotive Industry
4 Actual read range may vary based upon use case and attachment methods
Environmental Influences and Durability
RoHS EU Directive 2011/65/EU
ATEX/IECEx Certified
Shock 3 ft (1 m) to concrete/granite up to 100 cycles
Compression strength 725psi (5000 kPa)
IP classification IP68 (IEC 60529)
Operation temperature (read/write) -40°F to +185°F (-40°C to +85°C)
Application temperature -40°F to +482°F (-40°C to +250°C)
Temperature cycling test 30 Minutes at 250°C;1 hour cool-down;600 test cycles
Peak temperature +482°F / +250°C 6 hours duration
Humidity
Operational humidity
Storage humidity

5%-95% non-condensing
5%-95% non-condensing
Chemical resistance
No physical or performance changes in:
(tested in 186 hours exposure)

Salt water (15% salinity) / Ethanol / Acetone
Industrial rust lubricant / Industrial cleaner
Diesel fuel %

X